Fault Code Reference

Enphase Fault Codes

Enphase microinverters and IQ Battery storage. Module-level power electronics with per-panel monitoring, widely used in UK residential solar installations.

49
Fault codes
Inverter (49)

Common fault codes

ACVOOR
AC Voltage Out of Range
Check voltage at the consumer unit and at a socket near the inverter. Log over t…
ACFOOR
AC Frequency Out of Range
Check frequency in Enlighten or with a power quality analyser at the consumer un…
DC Res Low
DC Resistance Low (Ground Fault / GFDI)
Identify the specific microinverter(s) flagging this event in Enlighten. Inspect…
DC Too Low
DC Input Voltage Too Low
Check the affected module location in Enlighten. If shading is present at the ti…
DC Too High
DC Input Voltage Too High
Confirm only one module is connected per microinverter. Verify module Voc at STC…
Crit Temp
Critical Temperature
Check air gap behind modules meets Enphase minimum (typically 1 inch / 25 mm). C…

All Enphase fault codes

ACVOOR
AC Voltage Out of Range
Check voltage at the consumer unit and at a socket near the inverter. Log over t…
ACFOOR
AC Frequency Out of Range
Check frequency in Enlighten or with a power quality analyser at the consumer un…
DC Res Low
DC Resistance Low (Ground Fault / GFDI)
Identify the specific microinverter(s) flagging this event in Enlighten. Inspect…
DC Too Low
DC Input Voltage Too Low
Check the affected module location in Enlighten. If shading is present at the ti…
DC Too High
DC Input Voltage Too High
Confirm only one module is connected per microinverter. Verify module Voc at STC…
Crit Temp
Critical Temperature
Check air gap behind modules meets Enphase minimum (typically 1 inch / 25 mm). C…
Grid Gone
Grid Gone / No Grid
Check consumer unit — confirm grid is present and all MCBs/RCDs are reset
MI Not Reporting
Microinverter Failed to Report
Check Enlighten — note which MIs are not reporting and their positions on the ar…
ACVOOR Branch
AC Voltage High on Branch (Voltage Rise)
Measure voltage at the consumer unit and at the far end of the AC branch. A diff…
Pair Fail
Pairing / Discovery Failure
Confirm the MI is producing DC (check at module terminals) and AC is present. Op…
Prod Issue
Production Issue / Below Expected
Open Enlighten and check individual MI performance — identify which MIs are unde…
GW Offline
IQ Gateway Offline
Check broadband connection at the property. Confirm WiFi SSID and password have …
GW Amber LED
Gateway Amber Device LED
Open Installer Toolkit and check which MIs are not communicating. Note their pos…
Enlighten Stale
Enlighten Data Staleness
Check Gateway LEDs. Green network LED = online. Amber = connecting. Off = no net…
Bat Not Rep
IQ Battery Not Reporting
Check IQ Combiner and IQ System Controller LEDs — should be solid green. Check b…
Bat Not Chg
IQ Battery Not Charging
Check Enlighten for battery SoC. If at 100%, charging correctly stopped. Check b…
Bat Not Dchg
IQ Battery Not Discharging
Check SoC in Enlighten. If at minimum reserve (default 20%), battery is protecti…
Bat PCU Fault
IQ Battery PCU (Power Conversion Unit) Fault
Check battery temperature and ventilation. Power cycle the battery (follow Enpha…
G98/G99 Trip
G98/G99 Grid Disconnect Event
Check Enlighten for the time of the disconnect event. Cross-reference with grid …
Profile Not Set
Grid Profile Not Set
Open Installer Toolkit. Select the system and go to Grid Profile. Apply the corr…
FW Update Fail
Firmware Update Failure
Check Enlighten for update status. Confirm internet connection is stable. For MI…
Low SoC Rcv
Very Low SoC — Recovery Mode
Allow grid to recharge battery. This is a protection state — do not attempt to f…
GFDI Trip
Ground Fault Disconnect Interrupt
Identify the affected MI in Enlighten. Inspect DC Q-connectors and cables at tha…
Bat Temp Hi
Battery High Temperature Shutdown
Check the battery installation environment. IQ Battery 5P requires ambient below…
Bat Temp Lo
Battery Low Temperature -- Charge Restricted
Check battery ambient temperature. IQ Battery 5P requires minimum 0C for chargin…
Bat Cell Fault
Battery Cell Fault / Voltage Imbalance
Check Enlighten for battery State of Health and cycle count. A cell fault on a b…
Storm Guard
Storm Guard -- Battery Reserve Mode Active
This is not a fault. Storm Guard holds the configured reserve and limits normal …
P-SCH Fail
Production Schedule Failure
Check Gateway internet connectivity (ethernet or WiFi LED). Confirm broadband is…
Comm Timeout
Gateway Cloud Communication Timeout
Check Gateway network LED. Confirm broadband is working. If WiFi: confirm router…
Profile Mismatch
Grid Profile Does Not Match Detected Grid
Open Installer Toolkit, go to Grid Profile. Verify UK G98 (below 3.68kW export) …
5P: Solid Yellow
Battery Overtemperature Shutdown
Check ambient temperature at battery location (operating range: -20°C to 50°C). …
5P: Yellow 1 Flash
No Communication with IQ Gateway
Check IQ Gateway is powered and shows solid green Network LED. Check Comms Kit 2…
5P: Red 2 Flash
IQ Battery 5P Error State
Check Enlighten/Enphase app for 'PCU Fault' or specific event. Perform DC switch…
5P: Soft Pulse Red
DC Switch ON But No AC Supply
Check the battery's dedicated MCB in the IQ System Controller or electrical pane…
5P: Red 3 Flash
DC Switch is OFF — Normal State
Press the DC switch button on the front of the battery. LED should change to gre…
5P: G100 Lockout
G100 Export/Import Violation Lockout
This lockout can only be cleared by Enphase Support — call +44 1908 828 928. Do …
3T: Red 2 Flash
IQ Battery 3T Error State
FIRST CHECK: physically confirm the COMMS-KIT-01 Zigbee USB dongle is plugged in…
3T: No Discharge
IQ Battery 3T Not Discharging — Zigbee Comms Lost
Confirm COMMS-KIT-01 dongle is in IQ Gateway USB port. Without this dongle, IQ B…
GW: Net LED Red
IQ Gateway Connected to LAN But No Internet
Check broadband on another device. If no internet elsewhere — ISP or broadband o…
GW: Prod LED Red
IQ Gateway: One or More Microinverters Not Producing
Check time of day — solid red Production LED is normal at night and low-irradian…
GW: Dev Comm Red
IQ Gateway: One or More Devices Not Communicating
Open Installer App and identify which devices are not communicating. Note their …
Comb: All 4 Flash Red
IQ Gateway Rebooting
Wait 3 minutes. LEDs should return to normal operating state after boot. If a fi…
Comb: All 4 Flash Green
IQ Gateway Firmware Update In Progress
Do not power off, switch off MCBs, or disconnect internet during this sequence. …
EV: Solid Red
IQ EV Charger 2 — Fault State
Check the upstream MCB/RCBO feeding the charger has not tripped. Check earth con…
EV: Alternate Blink Red
PEN Fault — Do Not Use Charger
Do not attempt to reset or use the charger. A PEN fault is a serious supply safe…
EV: Orange
Charge Scheduled / Delayed (HEMS)
Check Enphase app schedule. If charging is needed now, override the schedule man…
Relay: Red Red
IQ Relay — No Grid Profile Set
Open Enphase Installer Toolkit. Connect to this system. Navigate to Grid Profile…
Relay: Green Red
IQ Relay — Frequency Protection Trip
Check grid frequency with a power quality meter. If frequency has normalised, re…
Relay: Stuck Open
IQ Relay Contactor Mechanically Failed Open
Confirm both LEDs are solid green and grid profile is set. Check with a voltage …
Full decision tree available in Faultpath Pro
Step-by-step fault diagnosis, offline access, and complete fault code coverage for solar & battery engineers.