DC Res Low

DC Resistance Low (Ground Fault / GFDI)

Ground Fault Detection and Interruption (GFDI) has detected low DC resistance to earth from the module wiring.

Module bypass diode failure causing frame-to-wiring shortDamaged module junction box sealWet wiring connector
STEP 1
Identify the specific microinverter(s) flagging this event in Enlighten. Inspect the module and wiring connector at that location for damage or moisture
STEP 2
Replace damaged connector or cable at the affected module. Check module junction box integrity
No wiring fault found and fault persists — module junction box failure, escalate