Enphase
Pair Fail

Pairing / Discovery Failure

IQ Gateway has failed to discover or pair with one or more microinverters during commissioning or after a reset.

MI not powered (no PV input or no AC)MI serial number not added to Enlighten systemPLC signal interferenceOutdated Gateway firmware
STEP 1
Confirm the MI is producing DC (check at module terminals) and AC is present. Open Installer Toolkit and run discovery scan
STEP 2
Check MI serial number is in the Enlighten system under the correct site. Ensure Gateway firmware is current
MI is powered (both DC and AC) and serial is in system but pairing fails — MI or Gateway hardware fault, escalate
Need full interactive diagnosis?
Faultpath walks you through decision trees, fault codes, and commissioning — built for solar & battery engineers.
Open Faultpath

More Enphase fault codes

ACVOOR
AC Voltage Out of Range
ACFOOR
AC Frequency Out of Range
DC Res Low
DC Resistance Low (Ground Fault / GFDI)
DC Too Low
DC Input Voltage Too Low
DC Too High
DC Input Voltage Too High