Enphase
P-SCH Fail

Production Schedule Failure

The IQ Gateway failed to retrieve or execute the production schedule from Enlighten (used for TOU and automation rules).

Gateway internet connection interrupted at schedule retrieval timeEnlighten cloud service interruptionOutdated Gateway firmware unable to parse schedule format
STEP 1
Check Gateway internet connectivity (ethernet or WiFi LED). Confirm broadband is working. Check Enlighten for any reported service interruptions
STEP 2
Check Gateway firmware version in Enlighten. If out of date, update via Enlighten Manager. Outdated firmware can fail to communicate with cloud API
Connectivity good, firmware current, but schedule failures continue -- escalate to Enphase support with Gateway serial number
Need full interactive diagnosis?
Faultpath walks you through decision trees, fault codes, and commissioning — built for solar & battery engineers.
Open Faultpath

More Enphase fault codes

ACVOOR
AC Voltage Out of Range
ACFOOR
AC Frequency Out of Range
DC Res Low
DC Resistance Low (Ground Fault / GFDI)
DC Too Low
DC Input Voltage Too Low
DC Too High
DC Input Voltage Too High