Enphase
ACFOOR

AC Frequency Out of Range

Microinverter has disconnected because grid frequency is outside the permitted window (47–52 Hz for UK G98).

Grid instabilityFrequency event on local network
STEP 1
Check frequency in Enlighten or with a power quality analyser at the consumer unit. Confirm it is a genuine frequency deviation
STEP 2
If the event is isolated and self-clearing, no action required. Log frequency history
Frequency persistently out of range — notify DNO