Enphase
DC Too High

DC Input Voltage Too High

Module voltage exceeds the microinverter's maximum input voltage.

Module Voc exceeds MI maximum (unlikely with correctly selected MI)Multiple modules connected to one MI port (incorrect installation)
STEP 1
Confirm only one module is connected per microinverter. Verify module Voc at STC does not exceed IQ MI maximum
STEP 2
Check wiring — ensure no parallel module connections have been made at a single MI
One module per MI confirmed and voltage is within spec — escalate
Need full interactive diagnosis?
Faultpath walks you through decision trees, fault codes, and commissioning — built for solar & battery engineers.
Open Faultpath

More Enphase fault codes

ACVOOR
AC Voltage Out of Range
ACFOOR
AC Frequency Out of Range
DC Res Low
DC Resistance Low (Ground Fault / GFDI)
DC Too Low
DC Input Voltage Too Low
Crit Temp