IQ Battery 5P is not accepting charge from PV or grid.

Battery SoC is already at target maximumGrid charging disabled in app settingsPV production insufficient to chargeBattery temperature out of charging range (<0°C or >50°C)
STEP 1
Check Enlighten for battery SoC. If at 100%, charging correctly stopped. Check battery temperature
STEP 2
Check Enphase app charging schedule and grid charging settings. Confirm PV is producing (check MI output)
Battery is below target SoC, temperature is normal, PV is producing but battery still not charging — escalate