Enphase
5P: Solid Yellow

Battery Overtemperature Shutdown

IQ Battery 5P LED is solid yellow — battery has shut down due to high internal temperature. Will resume when cool.

Ambient temperature above 50°CDirect sunlight on batteryInsufficient ventilation (less than 15cm clearance on all sides)Battery in unventilated enclosure
STEP 1
Check ambient temperature at battery location (operating range: -20°C to 50°C). Ensure all four sides have minimum 15cm clearance. Remove any materials stored against the battery
STEP 2
Provide shading if battery is in direct sunlight. Allow 30–60 minutes to cool — fault self-clears. Monitor Enlighten for temperature events
Solid yellow occurs at ambient temperatures below 40°C with adequate ventilation — thermal sensor or internal fault, escalate to Enphase +44 1908 828 928
Need full interactive diagnosis?
Faultpath walks you through decision trees, fault codes, and commissioning — built for solar & battery engineers.
Open Faultpath

More Enphase fault codes

ACVOOR
AC Voltage Out of Range
ACFOOR
AC Frequency Out of Range
DC Res Low
DC Resistance Low (Ground Fault / GFDI)
DC Too Low
DC Input Voltage Too Low
DC Too High
DC Input Voltage Too High