Enphase
EV: Orange

Charge Scheduled / Delayed (HEMS)

IQ EV Charger 2 LED is orange — a smart charge schedule (HEMS) is active and charging is deferred to a scheduled time or waiting for solar surplus.

Off-peak TOU charge schedule set in Enphase appSolar surplus threshold not yet metDynamic load management limiting current below minimum
STEP 1
Check Enphase app schedule. If charging is needed now, override the schedule manually in the app or on the charger
STEP 2
If solar divert is active, check that PV generation is sufficient to trigger minimum charge current (typically 6A minimum for Type 2 charging). Charger will not start below minimum current
No schedule is set and solar is generating above threshold but charger remains orange — dynamic load management or commissioning issue, check app settings
Need full interactive diagnosis?
Faultpath walks you through decision trees, fault codes, and commissioning — built for solar & battery engineers.
Open Faultpath

More Enphase fault codes

ACVOOR
AC Voltage Out of Range
ACFOOR
AC Frequency Out of Range
DC Res Low
DC Resistance Low (Ground Fault / GFDI)
DC Too Low
DC Input Voltage Too Low
DC Too High
DC Input Voltage Too High