G98/G99 Trip
G98/G99 Grid Disconnect Event
Microinverter(s) have disconnected due to a G98/G99 protection event (over/under voltage or frequency).
Common causes
Voltage or frequency excursion on gridExport causing voltage rise above G98 limitG99 settings incorrectly configured
What to check
STEP 1
Check Enlighten for the time of the disconnect event. Cross-reference with grid voltage/frequency at that time
STEP 2
For G99 sites, verify grid protection settings are set per DNO approved parameters. Check export limit is active
Escalate if
Events are frequent and grid parameters are confirmed within normal range — G98/G99 protection settings may need DNO recertification