Grid Lost
Grid Lost
Check the AC isolator and consumer unit — confirm grid is present with a voltage…
Error 26
Grid Voltage Out of Range
Measure the AC voltage at inverter terminals with a multimeter. Compare to G98 l…
Error 27
Grid Frequency Out of Range
Check frequency reading in Fox ESS app or on inverter display. Log frequency ove…
Error 28
10-Minute Average Voltage Fault
Check 10-minute average voltage in the app. If consistently above 253 V, check e…
Over Load
Inverter Overload
Check total connected AC load against inverter rated output. Identify any large …
Error 3
Isolation Fault (ISO Fault)
Disconnect all strings and test each string in turn with an insulation resistanc…

All FoxESS fault codes

Grid Lost
Grid Lost
Check the AC isolator and consumer unit — confirm grid is present with a voltage…
Error 26
Grid Voltage Out of Range
Measure the AC voltage at inverter terminals with a multimeter. Compare to G98 l…
Error 27
Grid Frequency Out of Range
Check frequency reading in Fox ESS app or on inverter display. Log frequency ove…
Error 28
10-Minute Average Voltage Fault
Check 10-minute average voltage in the app. If consistently above 253 V, check e…
Over Load
Inverter Overload
Check total connected AC load against inverter rated output. Identify any large …
Error 3
Isolation Fault (ISO Fault)
Disconnect all strings and test each string in turn with an insulation resistanc…
DCI Fault
DC Injection Fault
Power cycle the inverter. Allow a full self-test cycle
Ground Fault
Ground / Earth Fault
Check the PE (earth) terminal is secure at the inverter AC output. Confirm AC is…
Res Cur Fault
Residual Current Fault
Check all DC connectors for moisture or damage. Inspect cable runs for pinch poi…
Pv Volt Fault
PV Voltage Fault
Measure open-circuit voltage of each string before connecting. Compare to invert…
PvCon Dir Fault
PV Connector Polarity Fault
Power down DC isolator. Measure polarity of each string with a multimeter at the…
Error 14
BMS Lost / BMS Communication Error
Check BMS communication cable is firmly seated at both the battery and inverter …
Bms Int Fault
BMS Internal Fault
Check battery status in Fox ESS app. Note any specific BMS sub-codes shown
Bat Volt Fault
Battery Voltage Fault
Check battery SoC and voltage in the app. If SoC is at 0%, allow trickle charge …
Bat Power Low
Battery Power Low
This is a warning state — grid will recharge battery. Review minimum SoC setting…
Bat Relay Fault
Battery Relay Open/Short
Power cycle the battery. Check all cable connections
Temp Fault
Temperature Fault
Check ambient temperature at the installation location. Ensure ventilation clear…
Error 242
Meter Lost / Meter Communication Error
Check CT clamp is securely fitted on the correct conductor (usually grid import …
Error 11
SCI Fault / Internal Communication Error
Power cycle the inverter (AC off, DC off, wait 5 minutes). Check if fault clears…
Eps Relay Fault
EPS Relay Fault
Check EPS output wiring is connected to inverter EPS terminals (not AC output). …
Eps Over Load
EPS Overload
Calculate total load on EPS circuit. Reduce non-essential loads. Check EPS rated…
EEPROM Fault
Inverter / ARM EEPROM Fault
Power cycle the inverter. Check if fault clears
AFCI
Arc Fault Circuit Interruption
Inspect all DC connectors for burn marks, carbonisation, or damage. Check DC ter…
SW Bus Vol Fault
DC Bus Voltage Out of Range (Software)
Power cycle (AC off, DC off, wait 5 min, restore). Confirm DC input is within MP…
HW Bus Vol Fault
DC Bus Voltage Out of Range (Hardware)
Full power cycle: AC breaker OFF, DC isolator OFF, wait 10 min, restore. Check f…
BmsCellImbalance
Battery Cell Voltage Imbalance
Balance charge: force battery to 100% SoC and hold for 2-3 hours. BMS balancing …
MDSP SPI Fault
DSP Internal Communication Fault
Power cycle inverter. Check firmware in Fox Cloud -- all boards should be on the…
ECS: Under Voltage
Pack Under-Voltage Fault
Check SoC on Fox Cloud. If at 0% and battery has not charged for >7 days, deep d…
ECS: Over Voltage
Pack Over-Voltage Fault
Check inverter battery charge voltage setting in Fox Cloud matches the ECS batte…
ECS: Over Temp
Cell Over-Temperature Fault
Check ambient temperature at battery location. ECS operating range: 0–55°C disch…
ECS: PCS Comm Fail
BMS / PCS Communication Lost
Check CAN/RS485 cable is fully seated at the CM (controller module) bottom port …
ECS: Module Addr Fail
Module Addressing Failed
Count physical CS modules in the stack. Check DIP switch on CM matches. Inspect …
ECS: Relay Adhesion
Main Relay Stuck Closed (Welded)
Power off completely: DC switch off → hold POWER button for 5 seconds → wait 5 m…
ECS: Relay Not Close
Main Relay Failed to Close
Ensure inverter is powered up before pressing POWER button on battery. Correct s…
ECS: AFE Comm Fail
AFE Communication Failed
Power cycle the battery. Check if fault clears after restart
ECS: Cell 0V
Cell 0V Fault — Dead Cell or Broken Sense Wire
Do not attempt to charge. Check if the battery has been subject to deep discharg…
ECS: SOH Low
Battery State of Health Low
This is not a recoverable fault — the battery has completed its usable cycle lif…
EP: PCS Comm Fail
BMS / PCS Communication Lost
Check CAN cable at EP battery COM port and inverter BMS port. On parallel EP sys…
EP: Parallel Addr Fail
Parallel Addressing Failure
Check LINK OUT of Main unit connects to LINK IN of first Slave, and LINK OUT of …
EP: Relay Adhesion
Relay Stuck Closed
Power off: POWER switch off, wait 5 minutes. Power on. Check if fault clears
EP: Deep Discharge
Battery Deeply Discharged — Recovery Required
Connect to a charge source immediately. Force-charge via inverter if needed. Che…
EP: Black Start
Black Start Mode (EPS without grid)
To activate Black Start: press POWER button 3 times within 4 seconds. EPS output…
AIO: Iso Fault
Isolation Resistance Fault
Disconnect all PV strings and battery. Test IR of each independently at 500V DC.…
AIO: Bms Volt Low
Battery Voltage Low (AIO BMS Report)
Check SOC in Fox Cloud. If at minimum reserve, allow charge cycle to complete. C…
AIO: BmsCellImbalance
Battery Cell Voltage Imbalance
Allow the battery to complete a full charge/discharge cycle — this allows passiv…
AIO: Meter Lost
Meter / CT Communication Lost
Check CT clamp cable is plugged into the correct Meter/CT port on the AIO unit. …
AIO: EPS Over Load
EPS Output Overload
Identify and disconnect non-essential loads from the EPS circuit. Check the AIO …
AEB-1
Electronic Lock Fault
Remove EV plug completely. Re-insert firmly until it clicks. Retry charging. Che…
AEB-2
Emergency Stop Fault
Locate the E-stop button on the side of the charger. If pressed, rotate clockwis…
AEB-5
Output Overcurrent
Check maximum current setting in FoxSwitch app matches the installed cable ratin…
AEB-8
Electric Leakage / RCD Trip
Disconnect the EV. Check if fault clears when EV is disconnected. If it does, th…
AEB-9
L/N Reversal — Live and Neutral Swapped
Power off at MCB. Check wiring at charger terminal block — L=Brown/Black, N=Blue…
AEB-11
Charging Interface Overtemperature
Power off charger. Inspect socket contacts for burn marks, discolouration, or ar…
CT-reversed
CT Clamp Reversed — Solar Divert Not Working
Check CT clamp arrow: must point toward the charger (away from grid/supply). Rev…
WLan: Red 0.1s
Dongle Not Connected to Router
Connect phone/laptop to dongle's own hotspot (SSID: W-xxxxxxx, default password:…
WLan: Red 0.5s
Router Connected But Cloud Unreachable
Confirm broadband is working (test on another device). Port 443 must be open to …
WLan: No Light
Dongle Not Powered / Not Recognised
Unscrew and remove the dongle. Re-insert fully — triangle logo must face front o…