FoxESS
AEB-9

L/N Reversal — Live and Neutral Swapped

The charger has detected that the Live and Neutral conductors are swapped in the supply wiring.

Installation wiring error — L and N connected to wrong terminals
STEP 1
Power off at MCB. Check wiring at charger terminal block — L=Brown/Black, N=Blue, PE=Green/Yellow for single-phase UK supply. Correct polarity and restore
STEP 2
Verify polarity at consumer unit before reconnecting
Wiring corrected and fault persists — charger hardware detection fault, escalate