PV Connector Polarity Fault
PV connector polarity is reversed on one or more strings.
Common causes
MC4 connectors wired with reversed polarity
Labelling error during cable installation
What to check
STEP 1
Power down DC isolator. Measure polarity of each string with a multimeter at the inverter DC input terminals before connecting
STEP 2
Correct any reversed connections. Do not connect until polarity is confirmed
Escalate if
Polarity confirmed correct and fault persists — escalate