FoxESS
Eps Over Load

EPS Overload

The load on the EPS (backup) output exceeds the EPS rated capacity.

EPS circuit load exceeds inverter EPS ratingMotor loads with high inrush currentNon-linear loads
STEP 1
Calculate total load on EPS circuit. Reduce non-essential loads. Check EPS rated capacity in inverter spec
STEP 2
Remove motor or compressor loads from EPS circuit if inrush is causing the trip
Overload occurs with load well within EPS rating — possible hardware fault, escalate
Need full interactive diagnosis?
Faultpath walks you through decision trees, fault codes, and commissioning — built for solar & battery engineers.
Open Faultpath

More FoxESS fault codes