FoxESS
HW Bus Vol Fault

DC Bus Voltage Out of Range (Hardware)

Hardware-level DC bus voltage trip. Same root causes as SW Bus Vol Fault but detected by the protection circuit directly. More severe -- full power cycle required.

Large DC transient from PV or batterySurge event on DC sideInternal capacitor fault
STEP 1
Full power cycle: AC breaker OFF, DC isolator OFF, wait 10 min, restore. Check for visible surge damage at connectors or terminals
STEP 2
Check DC-side SPD (surge protection device) is intact and has not operated
Returns after power cycle with no DC overvoltage — internal fault, escalate