FoxESS
AIO: BmsCellImbalance

Battery Cell Voltage Imbalance

The AIO BMS has reported significant voltage spread between cells in the battery pack.

Normal aging causing cells to driftMissing full charge cycles (batteries kept at partial SOC)One cell degrading faster than others
STEP 1
Allow the battery to complete a full charge/discharge cycle — this allows passive balancing to run at high SOC. Balancing only occurs when cells are above 90% SOC
STEP 2
Check if the battery firmware is up to date via Fox Cloud. Check if there is a pattern of never reaching 100% SOC (time-of-use schedule preventing full charge)
Imbalance persists after several full charge cycles — possible cell degradation, escalate with Fox Cloud SOC history