Fault Code Reference

Solis Fault Codes

Solis hybrid and string inverters. Popular across UK residential installations, available through major distributors. Covers both legacy E-code and official alarm code ranges.

93
Fault codes
Inverter (93)

Common fault codes

E001
Grid Over-Voltage
Measure grid voltage at inverter AC terminals with multimeter. UK nominal 230V —…
E002
Grid Under-Voltage
Measure grid voltage at AC terminals. Check AC connections are tight and correct…
E003
Grid Over-Frequency
Fault is usually transient — wait 5 minutes for auto-recovery. Check Solis app f…
E004
Grid Under-Frequency
Usually transient — wait for auto-recovery. Persistent fault indicates grid or s…
E005
Grid Impedance High
Check all AC connections are tight — consumer unit, inverter terminals, any junc…
E010
PV Over-Voltage
Measure open-circuit string voltage with multimeter on a cold morning (highest V…

All Solis fault codes

E001
Grid Over-Voltage
Measure grid voltage at inverter AC terminals with multimeter. UK nominal 230V —…
E002
Grid Under-Voltage
Measure grid voltage at AC terminals. Check AC connections are tight and correct…
E003
Grid Over-Frequency
Fault is usually transient — wait 5 minutes for auto-recovery. Check Solis app f…
E004
Grid Under-Frequency
Usually transient — wait for auto-recovery. Persistent fault indicates grid or s…
E005
Grid Impedance High
Check all AC connections are tight — consumer unit, inverter terminals, any junc…
E010
PV Over-Voltage
Measure open-circuit string voltage with multimeter on a cold morning (highest V…
E011
PV Input Polarity Reversed
De-energise system. Check DC cable polarity with multimeter before reconnecting …
E012
Low Insulation Resistance
Check DC cables along full run for damage, crushing, or abrasion. Check panel ju…
E013
MPPT Input Fault
Measure open-circuit voltage on each string individually. Both strings on same M…
E020
Battery Communication Lost
Check CAN cable is connected to the correct port on both inverter (BAT CAN port)…
E021
Battery Over-Voltage
Check inverter battery charge voltage setting matches battery specification. Dyn…
E022
Battery Under-Voltage
Check inverter battery discharge cut-off voltage setting. Dyness Powerbox G2: mi…
E023
Battery Over-Temperature
Check battery location — must be out of direct sunlight. Ambient temperature mus…
E024
Battery Under-Temperature
This is a BMS protection — normal behaviour below 0°C. Battery will not charge u…
E025
Battery Over-Current
Check inverter charge and discharge current limits. Dyness Powerbox G2: max 100A…
E026
Battery BMS Fault
Check battery BMS status LEDs or display (Dyness Powerbox G2 has LED bar on fron…
E027
Battery Brand Mismatch
In Solis app or inverter menu: go to Battery Settings. Set battery brand correct…
E030
Inverter Over-Temperature
Check inverter location — must not be in direct sunlight. Minimum clearances: 30…
E031
Hardware Fault
Power cycle: turn AC breaker OFF, then DC isolator OFF. Wait 5 minutes. Restore …
E032
Firmware Fault / Version Mismatch
Check Solis app for available firmware update. If update interrupted, re-attempt
E033
Relay Fault
Power cycle inverter — AC OFF, DC OFF, wait 5 minutes, restore. Monitor for recu…
E040
Export Limit Fault — CT Clamp
Locate export limit CT clamp — must be on grid incomer (DNO side of consumer uni…
E041
Export Limit Exceeded
Check export limit setting in Solis app. G98 installs: typically 3.68 kW limit. …
OV-G-V
Grid Overvoltage (Alarm 1010)
If occasional, let it auto-recover. Check the grid standard is set correctly for…
UN-G-V
Grid Undervoltage (Alarm 1011)
Check the grid is present and the main breaker is on.
OV-G-F
Grid Over-Frequency (Alarm 1012)
Check the grid standard setting. The inverter reconnects automatically when freq…
UN-G-F
Grid Under-Frequency (Alarm 1013)
Check the grid standard setting. Auto-reconnects when frequency recovers.
Backfeed_Iac
AC Backfeed Current (Alarm 1014)
Restart the inverter.
NO-Grid
No Grid (Alarm 1015)
Check the AC isolator and main breaker are on.
G-PHASE
Unbalanced 3-Phase Grid (Alarm 1016)
Check all three phases are present and properly connected at the inverter.
G-F-FLU
Grid Frequency Fluctuating (Alarm 1017)
Confirm the grid connection is sound, then restart.
OV-G-I
Grid Output Overcurrent (Alarm 1018)
Confirm the grid is normal and AC cables are properly connected, then restart.
IGFOL-F
Grid Current Tracking Error (Alarm 1019)
Restart the inverter.
PHASE-FAULT
Abnormal Grid Phase Angle (Alarm 101A)
Check AC side wiring and phase rotation.
GRID-INTF.
Grid Interference (Alarm 1030)
Restart the inverter.
IG-AD
Grid Current Sampling Error (Alarm 1047)
Check AC connections are reliable, then restart.
OV-IgTr
Grid Current Transient Overcurrent (Alarm 1050)
Restart the inverter.
Vg-Sample
Grid Voltage Sampling Deviation (Alarm 1059)
Compare the AC voltage shown on the LCD with a multimeter reading at the termina…
L&PE FAULT
Low Resistance L to PE (Alarm F017)
Check the AC side wiring for a ground fault.
OV-DC
DC Overvoltage (Alarm 1020)
Check string Voc against the inverter maximum input and count panels in series.
BoostFal
DC Boost Circuit Fault (Alarm 1020)
Restart the inverter.
OV-BUS
DC Bus Overvoltage (Alarm 1021)
Check the PV input voltage is within the inverter range, then restart.
UNB-BUS
DC Bus Imbalance (Alarm 1022)
Restart the inverter.
UN-BUS
DC Bus Undervoltage (Alarm 1023)
Check whether the input voltage is too low for the inverter to run.
OV-DCA-I
DC1 Average Overcurrent (Alarm 1025)
Check the strings on MPPT 1 for faults and polarity.
OV-DCB-I
DC2 Average Overcurrent (Alarm 1026)
Check the strings on MPPT 2 for faults and polarity.
DC-INTF.
Abnormal DC Input Current (Alarm 1027)
Check the DC wiring for poor connection or damage.
Reve-DC
DC Reversed (Alarm 1028)
Isolate the system, then verify string polarity with a meter before reconnecting…
PvMidIso
PV Midpoint Insulation Low (Alarm 1029)
Note the timing. Early morning, late afternoon or rainy day reports are usually …
Vbus-Sam
DC Bus Sampling Fault (Alarm 102A)
Restart the inverter.
PV ISO-PRO
PV Insulation Protection (Alarm 1033)
Note the timing. Morning, late afternoon or rain reports are usually moisture an…
ILeak-PRO
Leakage Current Protection (Alarm 1034)
Reconnect strings one at a time to find the faulty string.
ARC- FAULT
DC Arc Detected (Alarm 1041)
Inspect MC4 connectors, inverter DC terminals, fuse blocks and junction boxes fo…
AFCI-Check
AFCI Self-Check Protection (Alarm 1040)
Restart the inverter.
ILeak-Check
Leakage Sensor Self-Check (Alarm 1039)
Restart the inverter.
INI-FAULT
DSP Initialising Fault (Alarm 1031)
Restart the inverter.
OV-TEM
Overtemperature (Alarm 1032)
Check the install location against the manual, direct sun, mounting angle and cl…
UN-TEM
Low Temperature (Alarm 103A)
Check the ambient temperature, then restart the inverter.
RelayChk-FAIL
Relay Self-Check Fault (Alarm 1035)
Restart the inverter.
DSP-B-FAULT
DSP Comms Fault (Alarm 1036)
Check the DSP software version exists on the LCD, then restart.
DCInj-FAULT
DC Injection Too High (Alarm 1037)
Confirm the grid and AC cables are normal, then restart.
12Power-FAULT
12V Supply Fault (Alarm 1038)
Restart the inverter.
IGBT-OV-I
IGBT Overcurrent (Alarm 1048)
Restart the inverter.
DSP-SelfCheck
DSP Firmware Mismatch (Alarm 1058)
Check the firmware version matches the inverter model number, then restart.
WORD5_B13
DSP Software Firmware Mismatch (Alarm 105A)
Check the 4th and 5th characters of the SN are consistent with the LCD model inf…
OV-Vbatt-H
Battery Hardware Overvoltage (Alarm 1051)
Check whether the battery circuit breaker has tripped.
OV-ILLC
LLC Hardware Overcurrent (Alarm 1052)
Check whether the backup load is overloaded, reduce it.
OV-Vbatt
Battery Overvoltage (Alarm 1053)
Check battery voltage against spec and battery settings, then restart.
UN-Vbatt
Battery Undervoltage (Alarm 1054)
Check battery SOC and voltage. Force-charge from grid if deeply discharged.
NO-Battery
Battery Not Connected (Alarm 1055)
Check the battery connections are sound.
OV-Vbackup
Backup Voltage High (Alarm 1056)
Check the backup terminal wiring is correct.
Over-Load
Backup Overload (Alarm 1057)
Switch off some backup loads, especially inductive ones.
CAN_Comm_FAIL
Battery CAN Comms Failure (Alarm 2012)
Check the CAN cable is seated at the inverter BAT port and the battery, with the…
Alarm1-BMS
Battery BMS Alarm 1 (Alarm 2015)
Restart the battery and check whether the fault returns.
BatName-FAIL
Wrong Battery Brand Selected (Alarm 2016)
Check the selected battery brand on the inverter LCD matches the installed batte…
Alarm2-BMS
Battery BMS Alarm 2 (Alarm 2017)
Restart the battery and check whether the fault returns.
LG-BMS-Fault
LG Battery BMS Fault (Alarm 2019)
Restart the battery.
LG-Comm-FAIL
LG Battery Comms Failure (Alarm 2021)
Check the comms cable, then restart the battery.
Failsafe
EPM Comms Failsafe (Alarm 2010)
Check the communication connection between the inverter and the EPM or meter.
MET_Comm_FAIL
Meter Comms Failure (Alarm 2011)
Check the meter communication cables.
DSP_Comm_FAIL
DSP Comms Failure (Alarm 2014)
Restart the inverter and check whether the fault returns.
DRM_LINK_FAIL
DRM Connection Failure (Alarm 2018)
Confirm the DRM cable connection is reliable, or disable DRM if not used.
CT-Failsafe
CT Connection Lost
Check the CT cables to the EPM.
M-ComFailSafe
Meter Comms Abnormal (EPM)
Restart the EPM.
M-VFailSafe
Meter Voltage Abnormal (EPM)
Restart the EPM.
RS485 Fail
RS485 Link Lost
Check the communication cables between the EPM and the affected inverters.
Fan Alarm
Internal Fan Fault
Check whether the internal fan starts, then restart the inverter.
Fan_H Alarm
External Fan Fault
Check the external fan, clean it per the manual.
DcSpdFail
DC Surge Protection Fault
Restart the inverter.
VgSpdFail
AC Surge Protection Fault
Restart the inverter.
Surge Alarm
Grid Surge Detected
No action needed if one-off. Restart if it keeps appearing.
Waiting
Waiting (Status)
Check the DC input voltage reaches the minimum starting voltage in daylight.
LimByEPM
Output Limited by EPM (Status)
Confirm whether export control is intended on this install. If yes, this is norm…