Solis
E011

PV Input Polarity Reversed

DC positive and negative connections are reversed on one or more strings.

Wiring error at DC isolator or inverter terminalsConnector polarity mistake
STEP 1
De-energise system. Check DC cable polarity with multimeter before reconnecting — red to +, black to −
STEP 2
Check MC4 connector assembly — verify pin genders match Solis MC4 requirements
Polarity confirmed correct but fault persists — internal MPPT issue, contact Solis support