Solis
E011
PV Input Polarity Reversed
DC positive and negative connections are reversed on one or more strings.
Common causes
Wiring error at DC isolator or inverter terminalsConnector polarity mistake
What to check
STEP 1
De-energise system. Check DC cable polarity with multimeter before reconnecting — red to +, black to −
STEP 2
Check MC4 connector assembly — verify pin genders match Solis MC4 requirements
Escalate if
Polarity confirmed correct but fault persists — internal MPPT issue, contact Solis support