Solis
E040

Export Limit Fault — CT Clamp

Export limiting CT clamp not reading correctly. Inverter cannot determine grid export level.

CT clamp not installedCT clamp reversedCT clamp on wrong cableCT cable disconnected
STEP 1
Locate export limit CT clamp — must be on grid incomer (DNO side of consumer unit). Arrow must point toward consumer unit
STEP 2
Check CT cable is connected to inverter CT input. Check Solis app — grid reading should show live import/export value
CT installed correctly and connected but grid reading zero — CT or input port fault, contact Solis support