Solis
E010
PV Over-Voltage
PV string voltage exceeds inverter maximum input voltage (Solis S6 max: 1000V DC).
Common causes
Too many panels in series for temperaturePanel specs not checked at installation
What to check
STEP 1
Measure open-circuit string voltage with multimeter on a cold morning (highest VOC condition). Must not exceed 1000V
STEP 2
Review string design — reduce panels in series if Voc (corrected for min temp) exceeds 1000V
Escalate if
String voltage within spec but fault persists — check MPPT input wiring
Need full interactive diagnosis?
Faultpath walks you through decision trees, fault codes, and commissioning — built for solar & battery engineers.
Open Faultpath
More Solis fault codes