myenergi
ZP-010

Over Voltage! / Under Voltage! / Bad Voltage Range!

AC supply voltage outside permitted range of 230V AC -16/+10% (approx 193-253V). Charging stops automatically.

Grid voltage outside specificationLong or undersized supply cable causing voltage dropVoltage rise from solar export
STEP 1
Wait — Zappi auto-resumes when voltage returns to range. Measure supply voltage at Zappi terminals.
STEP 2
If voltage drop under load: check supply cable size (4-10mm2) and length. If persistently high: notify DNO.
Voltage confirmed within range but fault persists — contact myenergi support