myenergi
ZP-009
RCD Tripped! (Code 29)
Internal 6mA DC RDC-DD earth leakage protection has tripped. Unit will not charge.
Common causes
Genuine earth leakage in EV or cableDamaged supply cable or Zappi wiringDamp conditions — transient leakageUpstream RCD also tripping
What to check
STEP 1
Unplug EV. Check if fault persists without EV. Check upstream RCD — reset if tripped.
STEP 2
Try a different EV to confirm if fault is EV-specific. Inspect supply cable for damage. Confirm IP glands are sealed.
Escalate if
Fault persists without EV, or upstream RCD trips repeatedly — investigate supply wiring, contact myenergi