myenergi
ZP-009

RCD Tripped! (Code 29)

Internal 6mA DC RDC-DD earth leakage protection has tripped. Unit will not charge.

Genuine earth leakage in EV or cableDamaged supply cable or Zappi wiringDamp conditions — transient leakageUpstream RCD also tripping
STEP 1
Unplug EV. Check if fault persists without EV. Check upstream RCD — reset if tripped.
STEP 2
Try a different EV to confirm if fault is EV-specific. Inspect supply cable for damage. Confirm IP glands are sealed.
Fault persists without EV, or upstream RCD trips repeatedly — investigate supply wiring, contact myenergi
Need full interactive diagnosis?
Faultpath walks you through decision trees, fault codes, and commissioning — built for solar & battery engineers.
Open Faultpath

More myenergi fault codes

ZP-001
Unknown Cable!
ZP-002
Pilot Problem!
ZP-003
Lock Failure!
ZP-004
Output Fault! (Code 24)
ZP-005
PE Fault! (Code 25)