Growatt
ShineLink: Device Off

ShineRFStick-X Not Paired with ShineLanBox

ShineRFStick-X (USB dongle in inverter) is in fast-flash mode indicating it cannot find its paired ShineLanBox.

ShineLanBox has been factory resetPower outage interrupted RF pairingShineLanBox replaced
STEP 1
Re-pair using the 4-step procedure: (1) Reset ShineLanBox (hold button until all 4 lights on), (2) Hold ShineRFStick-X reset 6s (solid blue), (3) Short-press ShineLanBox reset (Paired LED flashes), (4) Short-press ShineRFStick-X reset (Device LED on ShineLanBox begins flashing)
STEP 2
Wait 2 minutes after pairing sequence. ShineRFStick-X should change to slow flash (1s). If Device LED on ShineLanBox is already flashing before you start, pairing is already active — no action needed
Pairing sequence completes (Device LED flashing on ShineLanBox) but ShineRFStick-X still shows fast-flash after 5 minutes — RF interference or hardware fault, escalate
Need full interactive diagnosis?
Faultpath walks you through decision trees, fault codes, and commissioning — built for solar & battery engineers.
Open Faultpath

More Growatt fault codes

Error 200
AFCI — Arc Fault Detected
Error 201
Leakage Current High
Error 202
PV Voltage Too High
Error 203
PV Isolation Low (RISO)
Error 300
AC Voltage Out of Range