Growatt
Error 300

AC Voltage Out of Range

Grid voltage is outside the G98/G99 permitted window (typically 207–253 V). Inverter disconnects until voltage recovers.

High grid voltage from export (voltage rise)Weak grid / long cable run causing low voltageLoose AC terminal connection
STEP 1
Measure AC voltage at inverter terminals. Check ShinePhone for voltage history. Compare to G98 limits
STEP 2
If voltage is high due to export, enable Active Power Management in ShinePhone and set export limit. Check AC wiring is tight
Voltage persistently out of range with no obvious cause — notify DNO