Growatt
Error 414

DC Bus Overvoltage

The internal DC bus voltage inside the inverter has risen above its maximum limit.

PV input voltage too high under cold conditions (Voc rise)Grid disconnect event causing bus voltage spikeInternal component failure
STEP 1
Check PV string open-circuit voltage at inverter DC terminals -- particularly on cold mornings. If Voc exceeds inverter max, string design needs revision
STEP 2
Power cycle. Check ShinePhone for any preceding Error 307 (anti-islanding) event
PV voltage within spec and fault recurs -- internal component issue, escalate