Growatt
Error 413

AC Overcurrent -- Hardware Protection

Hardware-level overcurrent protection has tripped on the AC output. A deeper protection layer than Error 301.

Severe short circuit downstream of AC terminalsComponent failure in AC output stageAbnormal grid condition causing high circulating current
STEP 1
Isolate AC immediately. Inspect wiring for visible damage or burning. Do not restart without confirming no short circuit on the AC circuit
STEP 2
Test AC circuit insulation resistance before restarting. Confirm no short between L N PE
AC circuit tests clean but fault returns on restart -- inverter output stage fault, escalate immediately
Need full interactive diagnosis?
Faultpath walks you through decision trees, fault codes, and commissioning — built for solar & battery engineers.
Open Faultpath

More Growatt fault codes

Error 200
AFCI — Arc Fault Detected
Error 201
Leakage Current High
Error 202
PV Voltage Too High
Error 203
PV Isolation Low (RISO)
Error 300
AC Voltage Out of Range