PE Abnormal / Earth Fault
Earth continuity test has failed or PE conductor is absent.
Common causes
PE conductor not connected at inverter or isolator
Poor earth connection at consumer unit
Damaged AC cable with broken earth
What to check
STEP 1
Test earth continuity from inverter PE terminal to consumer unit earth bar. Must be <1 Ω
STEP 2
Check AC cable for damage. Ensure PE terminal is clamped correctly at both ends
Escalate if
Earth continuity confirmed and fault persists — escalate