Growatt
ARK: Charge Hi Temp

High Temperature During Charge

Cell temperature above charging temperature protection threshold. Charging halted. BMS ALM LED flashes green.

Ambient temperature above 45°CBattery in direct sunlightInsufficient ventilation clearances
STEP 1
Check ambient temperature at battery location. ARK operating range: 0–55°C discharge, 0–45°C charge. Ensure 300mm clearance on all sides. Remove from direct sunlight
STEP 2
Allow battery to cool and charging will resume automatically. Fault self-clears when temperature returns to safe range
Fault occurs in ambient temperatures below 35°C with adequate ventilation — NTC sensor fault, escalate
Need full interactive diagnosis?
Faultpath walks you through decision trees, fault codes, and commissioning — built for solar & battery engineers.
Open Faultpath

More Growatt fault codes

Error 200
AFCI — Arc Fault Detected
Error 201
Leakage Current High
Error 202
PV Voltage Too High
Error 203
PV Isolation Low (RISO)
Error 300