Faultpath
/
Fault Codes
/
Tesla
/
No Solar Production
Tesla
No Solar Production
No Solar Output for 24 Hours
No solar energy produced in the past 24 hours.
Common causes
Solar isolator or breaker off
RSD not reset
Arc fault lockout
Dead solar CT mimicking zero production
What to check
STEP 1
Check the solar AC isolator, breaker and RSD devices.
STEP 2
Check inverter alerts in Tesla One, arc fault lockout is a common cause.
Escalate if
Arc Fault Full Lockout or Solar Inverter Failure present, or no cause found on site
Need full interactive diagnosis?
Faultpath walks you through decision trees, fault codes, and commissioning — built for solar & battery engineers.
Open Faultpath
More Tesla fault codes
ALT-01
Breaker Open
ALT-02
Device Offline / Gateway Offline
ALT-03
Backup Failed / No Power During Outage
ALT-04
Calibration Discharge to 0%
ALT-05
CT Reading Error — Negative Solar or Grid