Grid Outage
Tesla
Grid Outage
Grid Outage, Running on Backup
Gateway detected grid loss or disturbance and islanded the home onto Powerwall backup.
Common causes
Real DNO outage
Supply quality issue
Loose grid-side connection
What to check
STEP 1
Confirm whether a real outage exists. If yes, no action, reconnection is automatic.
STEP 2
If the grid is live, check Gateway grid-side connections and the main fuse or isolator.
Escalate if
Repeated islanding on a healthy grid with tight connections