SG-047 · ID 4 (Optimizer)

Optimizer Input Overvoltage

PV voltage at optimizer input has exceeded maximum allowed input voltage. Displayed fault ID: 004.

PV module cable to optimizer unreliable or incorrectOpen-circuit voltage of PV module exceeds optimizer maximum input voltageAbnormal module open-circuit voltage
STEP 1
Check cables between optimizer and PV module are reliably and correctly connected. Verify Voc of PV module does not exceed optimizer maximum input voltage.
STEP 2
If Voc within spec, check for wiring faults causing voltage spikes.
Connections and Voc confirmed within spec but fault persists — contact Sungrow support