Sungrow
SG-003 · ID 8

Grid Overfrequency

AC grid frequency has exceeded upper frequency protection threshold. Auto-reconnects when frequency normalises. Displayed fault ID: 008.

Grid frequency genuinely above thresholdFrequency protection parameters set too low
STEP 1
Wait — inverter auto-reconnects. If recurring, measure actual grid frequency and compare to threshold.
STEP 2
If frequency exceeds set range, contact DNO/DNSP. Review frequency protection parameters via App or LCD.
Fault persists after parameter review — contact Sungrow support