Sungrow
SG-013 · IDs 264–283

MPPT Reverse Connection

Reverse polarity detected at MPPT input. IDs 264–279 = strings 1–16.

MC4 connectors reversed at MPPT input during installation
STEP 1
SAFETY: Wait for string current to drop below 0.5 A. Disconnect DC switch. Verify polarity of MPPT input connections for identified string.
STEP 2
Correct any reversed connectors. Restore DC switch and monitor.
Polarity confirmed correct but fault persists — contact Sungrow support