Sungrow
SG-012 · IDs 548–563, 580–595

PV String Abnormal Alarm

Abnormal voltage or current on a PV string. IDs 548–563 = strings 1–16; IDs 580–595 = strings 17–32. System continues operating but affected string is degraded.

PV modules shaded or soiledLoose wiring on panel junction box or combinerDC fuse blown or damagedModule degradation or failure
STEP 1
Check whether affected string's modules are shaded or dirty. Remove shading sources and clean panels if needed.
STEP 2
Inspect string wiring — check all connections are securely seated. Check DC fuse(s) for the string — replace any blown fuse.
Shading, cleaning, wiring, and fuse checks all pass but alarm persists — contact Sungrow support
Need full interactive diagnosis?
Faultpath walks you through decision trees, fault codes, and commissioning — built for solar & battery engineers.
Open Faultpath

More Sungrow fault codes

SG-001 · IDs 2,3,14,15
Grid Overvoltage
SG-002 · IDs 4,5
Grid Undervoltage
SG-003 · ID 8
Grid Overfrequency
SG-004 · ID 9
Grid Underfrequency
SG-005 · ID 10