Fault Code Reference

SolarEdge Fault Codes

SolarEdge inverters with DC power optimisers. Widely deployed across UK residential solar with monitoring via the mySolarEdge platform and SetApp commissioning.

49
Fault codes
Inverter (49)

Common fault codes

2xF
DC Overvoltage Error
Turn OFF inverter ON/OFF switch. After 5 minutes verify LCD shows low safety vol…
2x10
Vref Voltage Error
Verify proper inverter clearances (top, bottom, sides)
2x11
Over Temperature
Verify clearances: min 200mm top, 150mm left/right, 100mm bottom
2x13
Software Error
Note exact error code and current software version
2x18
Broken or Unconnected Temperature Sensor
Inspect temperature sensor connector (usually near heat sink)
18x / F-Isolation
DC Isolation Fault (Ground Leakage)
Check all DC cables for visible damage, pinch points, or rodent damage. Inspect …

All SolarEdge fault codes

2xF
DC Overvoltage Error
Turn OFF inverter ON/OFF switch. After 5 minutes verify LCD shows low safety vol…
2x10
Vref Voltage Error
Verify proper inverter clearances (top, bottom, sides)
2x11
Over Temperature
Verify clearances: min 200mm top, 150mm left/right, 100mm bottom
2x13
Software Error
Note exact error code and current software version
2x18
Broken or Unconnected Temperature Sensor
Inspect temperature sensor connector (usually near heat sink)
18x / F-Isolation
DC Isolation Fault (Ground Leakage)
Check all DC cables for visible damage, pinch points, or rodent damage. Inspect …
1x / Night Mode
Night Mode / Standby (Insufficient Irradiance)
If dark or overcast: wait — inverter will restart automatically when irradiance …
2x19
PV Solar Array Isolation Fault
Check PV installation for isolation problems and ground leakage
2x1A
Internal Communication Fault
Verify all optimizer connectors are securely seated
2x1C
Internal Fault
Note exact error code and timing of occurrence
2x1D
Line to Neutral Voltage Above Threshold
Check grid connection — all AC breakers properly connected
2x1E
Line to Neutral Voltage Below Threshold
Check grid connection with multimeter (verify 230V present)
33xD
Inverter Fan Not Working
Check physical cable connection to fan
33x10
Internal Communication Error
Power cycle inverter (OFF 30 seconds, then ON)
33x19
AC Voltage Surge
Check AC connection to inverter — all terminals secure
33x86
DC SPD Not Functioning
Validate DC SPD board is installed per installation guide
33x85
AC SPD Not Functioning
Validate AC SPD board is installed per installation guide
33x9C
AC Terminal Temperature Critical
Verify AC lugs are properly installed
33x47
Inverter Temperature Critical
Verify inverter clearances per installation guide (200mm top minimum)
Ground Current RCD
Ground Current - RCD (2xA/2x25/2x26, 3P 8x2B/8x2C/8x39)
Shock hazard. Inverter switch OFF, wait 5 minutes for capacitors, isolate AC, di…
RCD Current Surge
RCD Current Surge (3P, 8x51)
Follow the isolation fault procedure, string by string isolation with megger tes…
Error 28
RCD Sensor Error (2x1C, 3P 124/8x5B)
Power cycle the inverter fully.
Arc Fault
Arc Fault Detected (147/150/151, 3x11/2x96/2x97)
Inspect DC wiring for loose MC4s, damaged insulation and corroded joints before …
Error 152
Arc Detector Self-Test Failed (2x98)
Power cycle fully (DC and AC).
AC Voltage Too High
AC Voltage Too High (31/33, 2x1F/2x21, 3P 64-66)
Verify the country grid code is correct (UK G98/G99).
AC Voltage Too Low
AC Voltage Too Low (32/41, 2x20/2x29, 3P 61-69)
Check for a tripped supply breaker or area outage.
AC Current Surge
AC Current Surge (9/13, 2x9/2xD)
Check the AC connection to the inverter.
AC Freq Too High
AC Frequency Too High (34, 2x22, 3P 79-81)
Verify the country grid setting, then allow automatic reconnection.
AC Freq Too Low
AC Frequency Too Low (35, 2x23, 3P 82-84)
Verify the country grid setting, then allow automatic reconnection.
Islanding
Islanding Detected (40, 2x28, 3P 87/89)
Check the board for tripped breakers and confirm whether there is an area outage…
Grid Sync Error
Grid Sync Error (3P, 78/8x2D)
Measure and log grid voltage and frequency stability at the inverter.
VLL Range
Line-to-Line Voltage Out of Range (3P, 70/71, 8x25/8x26)
Verify the country setting, then measure phase to phase voltages.
Wrong AC Connection
Wrong AC Connection (3P, 112/8x4F)
Swap L1 and L2, or L2 and L3, at the inverter AC terminals and re-test.
AC Over Current
AC Over Current (3P, 91-93, 8x3A-8x3C)
Power cycle the inverter.
DC Injection
DC Injection (36, 2x24, 3P 72-75)
Power cycle the inverter and record how often it occurs.
No Country Selected
No Country Selected (44, 2x2C)
Select the correct country grid code (UK G98/G99) in SetApp or the LCD menu and …
UDC Range
DC Voltage Out of Range (145/146, 2x91/2x92, 3P 102/103)
Power cycle the inverter.
Error 105
Temperature Too Low (3P, 105/8x48)
Check ambient temperature is within the datasheet range.
Error 26
Faulty AC Relay (3P 122/8x59)
Power cycle the inverter once.
Hardware Error
Hardware Error (16/149/153 and 3P family)
Full power cycle, record the exact code, sub-code and time.
SW Error
Software Error (multiple codes)
Power cycle the inverter.
S_OK Lost
Server Communication Loss (S_ERR)
Check the router and internet connection.
Meter Comms Loss
No Communication With Meter (RS485)
Check connections on the inverter communication board.
P_OK Mismatch
Optimizer Not Communicating (P_OK count low)
Run pairing (monitoring Layout right-click, or SetApp/LCD).
Module Mismatch
Module Voltage Mismatch (bypass diode)
Compare module voltage in monitoring Analysis against the panel Vmpp spec.
SenseConnect
SenseConnect Safety Lock (S-Series)
Check inverter firmware is 4.17 or higher, upgrade if lower.
Battery Comms Loss
No Communication With Battery
Verify battery DC and comms connections at both ends.
Battery Breaker Tripped
Battery Circuit Breaker Tripped
Full power down in the documented order, then power up in reverse order.
G100 Restriction
G100 Export Restriction Active (UK)
Resolve any meter communication fault first, export limiting needs the meter.
Full decision tree available in Faultpath Pro