SolarEdge
UDC Range

DC Voltage Out of Range (145/146, 2x91/2x92, 3P 102/103)

DC input voltage above (UDC Max) or below (UDC Min) the operating window. Abnormal on SolarEdge since optimizers regulate string voltage.

Optimizer not regulatingString design outside rulesNon-communicating optimizers holding safety voltage
STEP 1
Power cycle the inverter.
STEP 2
Verify string design against SolarEdge rules and check for non-communicating optimizers.
Persists after re-pairing
Need full interactive diagnosis?
Faultpath walks you through decision trees, fault codes, and commissioning — built for solar & battery engineers.
Open Faultpath

More SolarEdge fault codes

2xF
DC Overvoltage Error
2x10
Vref Voltage Error
2x11
Over Temperature
2x13
Software Error
2x18
Broken or Unconnected Temperature Sensor