SolarEdge
Ground Current RCD

Ground Current - RCD (2xA/2x25/2x26, 3P 8x2B/8x2C/8x39)

Internal residual current monitor measured high ground leakage, usually insufficient insulation to earth.

PV string insulation breakdownMoisture in connectors or DC isolatorsDamaged string cable
STEP 1
Shock hazard. Inverter switch OFF, wait 5 minutes for capacitors, isolate AC, disconnect DC.
STEP 2
Reconnect each DC string separately and power up until the error reappears to find the faulty string.
No faulty string found, or error appears with all strings disconnected