Sigenergy
5102

Low Insulation Resistance

Resistance of positive and negative busbars to ground is too small.

DC cable short circuit or brokenPositive/negative poles shorted to groundMoisture at DC connections
STEP 1
Check DC cable for short circuit or broken cable. Check positive and negative poles of DC cable are not shorted to ground
STEP 2
If fault occurs on rainy days, recheck after weather improves
Cables confirmed correct in dry conditions and fault persists — submit fault report via mySigen App > Support > Troubleshooting
Need full interactive diagnosis?
Faultpath walks you through decision trees, fault codes, and commissioning — built for solar & battery engineers.
Open Faultpath

More Sigenergy fault codes

1001
Software Version Mismatch
1002
Low Insulation Resistance
1003
Over-Temperature
1004
Equipment Fault
1005
System Grounding Fault