Sigenergy
5004

Charging Cable Fault

Charging cable has abnormal current-carrying capacity (socket-type charger only).

Charging cable current-carrying capacity outside specFaulty cable PP-PE resistance
STEP 1
Remove charging cable. Use multimeter to measure resistance between PP and PE. Expected: 100, 220, 680, or 1500 ohm (±3%)
STEP 2
If resistance is correct but fault persists, contact technical support. If resistance is incorrect, replace the charging cable
Cable replaced and fault persists — contact technical support
Need full interactive diagnosis?
Faultpath walks you through decision trees, fault codes, and commissioning — built for solar & battery engineers.
Open Faultpath

More Sigenergy fault codes

1001
Software Version Mismatch
1002
Low Insulation Resistance
1003
Over-Temperature
1004
Equipment Fault
1005
System Grounding Fault