Neutral Line Loose or AC Wiring Abnormal

Neutral conductor is not firmly connected, or AC wiring has an abnormality.

Loose neutral connection at AC terminalAC wiring error — incorrect terminationN conductor missing or broken
STEP 1
Isolate inverter (AC off, DC off). Check neutral terminal at AC connection block — confirm firmly torqued (M5: 2.0 N·m)
STEP 2
Check neutral wiring from consumer unit to inverter — confirm continuity and correct termination
Neutral connection confirmed correct and fault persists — contact Sigenergy support via mySigen App > Support > Troubleshooting