Sigenergy
1006

PV String Overvoltage

One or more strings have input voltage exceeding maximum. ID1-ID16 indicate which string is affected.

Too many panels in seriesOpen-circuit voltage exceeds maximum input voltage
STEP 1
Machine will restart after environment returns to normal. Measure PV voltage of alarm string to confirm it exceeds system voltage
STEP 2
If string voltage is too high, reduce number of panels in that string. Disconnect DC switch before adjusting
Fault persists and string configuration is correct — submit fault feedback via APP > Service > Troubleshooting
Need full interactive diagnosis?
Faultpath walks you through decision trees, fault codes, and commissioning — built for solar & battery engineers.
Open Faultpath

More Sigenergy fault codes

1001
Software Version Mismatch
1002
Low Insulation Resistance
1003
Over-Temperature
1004
Equipment Fault
1005